|
Who's Online
There currently are 6042 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a great and complete Service Manual for the Sharp GF8585HB. Giving full and detailed technical insight. Good to find these manuals online.
;
Everything was ok with the manual. If I have a small complaint, is that I ordered it during the weekend and I think you guys were closed. But I did receive it late Sunday. I will surely order from you again
;
Best Service! Very fast and easy to handle. Fast Download an you can come back every day to download again
;
Very good quality, no parts are missing and everthing is readable.
Thank you very much. :-)
;
This manual is all I need to check and repair my equipment. Thank you....
CP830Service Manual
5.3.2.5 Luma Sharpness Enhancer (LSE) Sharpness is one of the most critical features for optimum picture quality. This important processing is performed in the LSE circuitry of DDP 3315C. It consists of the dynamic peaking, the luma transient improvement (LTI) and an adaptive mixer. The luma input signal is processed in the peaking and LTI block in parallel. Both output signals are combined in the mixer depending on the selected LSE characteristic. 5.3.2.6 Dynamic Peaking The dynamic peaking improves the details of a picture by contour emphasis. It adapts to the amplitude and the frequency of the input signal. Small detail amplitudes are sharpened, while large detail amplitudes stay nearly unmodified. 5.3.2.7 Luma Transient Improvement (LTI) For small detail amplitudes the dynamic peaking is the most appropriate processing to improve the sharpness. However, for large amplitudes even small over-and/ or undershoots of the peaking are too annoying. The luma transient improvement enhances the slope of picture detail without these effects by a non-linear processing. The contour correction signal calculated in this block, is limited to the adjacent extreme values to prevent over- and undershoots. The LTI features an adjustable gain control and an adjustable coring threshold to prevent the enhancement of small noise amplitudes. 5.3.2.8 Mixing of Dynamic Peaking and LTI The contour correction signals of the dynamic peaking and the LTI block are combined by the mixer. Controlled by the amplitude of a picture edge, this circuitry fades between these two signals. Thus, small and medium picture detail is enhanced by contour emphasis (peaking) and large picture detail is enhanced by step-improvement (LTI). 5.3.2.9 Chroma Transient Improvement The intention of this block is to enhance the chroma resolution. A correction signal is calculated by differentiation of the colour difference signals. The differentiation can be selected according to the signal bandwidth, e.g. for PAL/NTSC/SECAM or digital component signals, respectively. The amplitude of the correction signal is adjustable. Small noise amplitudes in the correction signal are suppressed by an adjustable coring circuit. To eliminate wrong colours , which are caused by over and undershoots at the chroma transition, the sharpened chroma signals are limited to a proper value automatically.
-50-
|
|
|
> |
|