Who's Online
There currently are 5730 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
;
I will definitely be back for more information when I need it.
;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
10-2. CONVERGENCE ADJUSTMENTS
B. CIRCUMFERENCE CONVERGENCE ADJUSTMENT
NOTE : Before attempting any purity adjustments, the
receiver should be operated for at least 15 minutes. A. CENTER CONVERGENCE ADJUSTMENT 1) Receive crosshatch pattern with a crosshatch signal generator. 2) Adjust the BRIGHTNESS and CONTRAST Controls for a good picture. 3) Adjust two tabs of the 4-Pole Magnets to change the angle between them (See Fig. 3) and superimpose red and blue vertical lines in the center area of the picture screen. (See Fig. 4) 4) Turn both tabs at the same time keeping their angles constant to superimpose red and blue horizontal lines at the center of the screen. (See Fig. 4) 5) Adjust two tabs of 6-Pole Magnets to superimpose red/blue line with green on top of each other. Adjusting the angle affects the vertical lines and rotating both magnets affects the horizontal lines. 6) Repeat adjustments 3), 4), 5) keeping in mind red, green and blue movement, because 4-Pole Magnets and 6-Pole Magnets interact and make dot movement complex.
NOTE : This adjustment requires Rubber Wedge Kit.
1) Loosen the clamping screw on deflection yoke to allow the yoke to tilt. 2) Place a wedge as shown in figure 2 temporarily. (Do not remove cover paper on adhesive part of the wedge.) 3) Tilt front of the deflection yoke up or down to obtain better convergence in circumference. (See Fig. 4) Push the mounting wedge into the space between picture and the yoke to hold the yoke temporarily. 4) Place other wedge into bottom space and remove the cover paper to stick. 5) Tilt front of the yoke right or left to obtain better convergence in cicumference. (See Fig. 4) 6) Hold the yoke position and put another wedge in either upper space. Remove cover paper and stick the wedge on picture tube to hold the yoke. 7) Detach the temporarily mounted wedge and put it in another upper space. Stick it on picture tube to fix the yoke. 8) After placing three wedges, re-check overall convergence. Tighten the screw firmly to hold the yoke tightly in place. 9) Stick 3 adhesive tapes on wedges as shown in figur32.
4-POLE MAGNETS PURITY MAGNETS 4DJUST THE ANGLE (VERTICAL LINES)
CONSTANT
CONVERGENCE MAGNET ASSEMBLY
Fig. 3
ROTATE TWO TABS AT THE SAME TIME (HORIZONTAL LINES)
ADJUSTMENT OF MAGNET
BLUE RED
RED/BLUE GRN
BGR B G R B G R BGR RGB R G B BGR
BLUE RED
RED/BLUE GRN
R G B
4-Pole Magnets Movement
6-Pole Magnets Movement Incline the Yoke up(or down) Incline the Yoke right(or left)
Center Convergence by Convergence Magnets
Circumference Convergence by DEF. Yoke
Fig. 4 Dot Movement Pattern