Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
;
Very detailed product, also it is a scanning from original, very useful if you have to service this type of amplifier ! Very good product, very hard to find!
;
the Manual was made available as promised, the scans were excellent..Good Work !!!
;
It's complete and helpful manual with good quality of scan. Thanks very much.
;
The service was quick and simple, finding the service manual easy and it appears to be the original with colour schematics. It contained the info I was after and so sorted the problem.
I have copied it to CD and attached the envelope to the inside back cover of the owners manual. Good manual and excelent service. Robin Wood, Wood Electronics, New Zealand.
5. OCP (OVER CURRENT PROTECTION) CIRCUIT
This circuit is designed to protect the circuit from over current due to overload occurred at the rear of 123[V] line 1) CONFIGURATION OF OCP CIRCUIT
2) EXPLANATION OF THE OPERATION There is very little voltage drop at R423 of 123[V] line. In case that the overload occurs at the rear of 123[V] line, the increase of the voltage drop at R423 bring down the base voltage of the Q407 os as to drive the Q407 Because of the overload at the rear of the R423, the voltage of the point decreases. And this makes Q407 turn on so that a voltage is applied to the #31 of l701. In case that OCP operates by the #31 of the l1701, the set is protected by power off (#42 of l1701 LOW).