Who's Online
There currently are 5868 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
El producto satisface las necesidades del servicio t
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
ELECTRICAL ADJUSTMENTS
ADJUSTMENT PROCEDURES
Read and perform these adjustments when repairing the circuits or replacing electrical parts or PCB assemblies. CAUTION: Inferior silicon grease can damage transistors. When replacing transistors, use only specified silicon grease. Remove all old silicon before applying new silicon.
2. COMB FILTER
CONDITIONS MODE-STOP Input Signal-NTSC Multiburst (VIDEO IN JACK) INSTRUCTIONS 1. Connect the video signal generator to VIDEO IN JACK. 2. Connect CH-1 on the oscilloscope to TJ303 and CH-2 to TJ304. 3. Trigger the scope with CH1. 4. Adjust R494 until the 3.58MHz component of multiburst signal becomes minimum. (Refer to Fig. 5-2)
1. PG SHIFTER
CONDITIONS MODE-PLAYBACK Input Signal-Alignment Tape (DN-1). INSTRUCTIONS 1. Connect CH-1 on the oscilloscope to pin ¤� of PT01 and CH-2 to Video output JACK. 2. Adjust R595 so that the waveform of the oscilloscope measures 6.5±0.5(H) at both leading and trailing edges. (Refer to Fig. 5-1-A, B)
Fig 5-2
CH-2
3. AUDIO BIAS
6.5H CH-1
CONDITIONS MODE-RECORD (SP MODE) Input Signal-Audio Signal : No Signal INSTRUCTION Connect the AC voltmeter as shown, then adjust the voltage to 3.0±0.1mVrms with R292 (Refer to fig. 3-6).
Fig 5-1-A
CH-2
A/C Head. AC Voltmeter TP2 TP1 (GND)
CH-1 6.5H
Fig 5-1-B
Fig 5-3