Text excerpt from page 30 (click to view)
7. To remove high voltage capacitor. (1) Remove the screw (F09) which secure the grounding ring terminal of diode (F10) and capacitor holder (F08). (2) Remove the capacitor holder (F08) with capacitor (F11). (3) Reverse the above steps for reassembly.
High voltage circuit wiring